High Performance PTCA Balloons for Vessel Preparation

ORIGIN SC and ORIGIN NC are particularly appropriate in a pre-dilation role and can be used in conjunction with a drug-eluting balloon such as SELUTION SLR to prepare the vessel. They can also be used on their own to pre-dilate a vessel prior to stent implantation or post-dilate a coronary stent to achieve accurate and controlled stent expansion.

Origin SC - Semi-Compliant PTCA Balloon Catheter

Origin SC is a very low profile semi-compliant PTCA balloon catheter with enhanced trackability, crossability and pushability to access your most challenging lesions.

  • Offering a broad portfolio of sizes, including 1.00 mm, 1.25 mm, 1.50 mm and 1.75 mm balloon diameters to treat very small vessels and complex cases.
  • Lowest crossing profile compared to the best-in-class semi-compliant PTCA balloons.1
Origin NC - Non-Compliant PTCA Balloon Catheter

Origin NC is a non-compliant PTCA balloon catheter that combines high pressure tolerance and controlled compliance with an optimal crossing profile for the most challenging cases.

  • Offering a broad portfolio of sizes for all clinical situations in your daily practice, with balloon diameters ranging from 2.00 mm – 5.00 mm and lengths from 8 mm – 20 mm.
  • Origin NC’s low crossing profile ensures easy crossing, deliverability and controlled balloon expansion to optimize dilatation of challenging, heavily calcified lesions.
  • Minimal balloon longitudinal growth (3%) ensures focused dilatation force on the target lesion.2
  1. Data on file at MedAlliance CardioVascular SA.
  2. Data on file at BrosMed Medical Co. Ltd.

Ordering Information

Origin SC - Semi-Compliant PTCA Balloon Catheter
Balloon
Diameter (mm)
Balloon Length (mm)
1012152030
1.00OS1010OS1012OS1015OS1020OS1030
1.25OS1210OS1212OS1215OS1220OS1230
1.50OS1510OS1512OS1515OS1520OS1530
1.75OS1710OS1712OS1715OS1720OS1730
2.00OS2010OS2012OS2015OS2020OS2030
2.25OS2210OS2212OS2215OS2220OS2230
2.50OS2510OS2512OS2515OS2520OS2530
3.00OS3010OS3012OS3015OS3020OS3030
3.50OS3510OS3512OS3515OS3520OS3530
4.00OS4010OS4012OS4015OS4020OS4030
Origin NC - Non-Compliant PTCA Balloon Catheter
Balloon
Diameter (mm)
Balloon Length (mm)
81012161820
2.00ON2008ON2010ON2012ON2016ON2018ON2020
2.25ON2208ON2210ON2212ON2216ON2218ON2220
2.50ON2508ON2510ON2512ON2516ON2518ON2520
2.75ON2708ON2710ON2712ON2716ON2718ON2720
3.00ON3008ON3010ON3012ON3016ON3018ON3020
3.25ON3208ON3210ON3212ON3216ON3218ON3220
3.50ON3508ON3510ON3512ON3516ON3518ON3520
3.75ON3708ON3710ON3712ON3716ON3718ON3720
4.00ON4008ON4010ON4012ON4016ON4018ON4020
4.50ON4508ON4510ON4512ON4516ON4518ON4520
5.00ON5008ON5010ON5012ON5016ON5018ON5020

Customer Service:

Email: customerservice@medalliance.com

Germany

Tel:  +49 21 023 903 103
Fax: +49 21 023 903 104

UK

Tel:   +44 204 538 3600
Fax:  +44 204 538 3600

Other Countries

Tel:  +41 22 363 78 95
Fax: +41 22 363 78 99

SELUTION SLR and CAT are trademarks of M.A. Med Alliance SA.
SELUTION SLR Sirolimus Eluting PTCA & PTA Balloon Catheter - CE Mark Approved. Not available for sale in United States.
Indications, contraindications and warnings can be found in the instructions for use supplied with each device.